Food & BeverageSoutheast AsiaIllustrative project scenario

Palm oil mill effluent solids recovery

A plate and frame press for batch solids recovery, with stainless wetted parts for washdown.

Palm oil mill effluent treatment area

Background

A mill wanted to recover residual solids from process effluent and reduce the load on downstream treatment.

Duty conditions

Effluent at 1–6 % solids, oily, 40–70 °C, batch collection through the day.

Delivery scope

Pilot trial, press supply, cloth selection and a washdown procedure for the food environment.

What needed attention

Oil in the feed changed cloth behaviour noticeably. A pre-collection tank improved consistency before filtration.

What carried over

When feed quality varies through the day, buffer capacity is part of the filtration design.

Discuss a similar project

Send the duty and the constraints. We will come back with the model, plate and cloth combination and the points that need confirming.